blueprint: name: Inovelli LED Temperature Display description: Display the temperature on the LED strip of an Inovelli VZM31-SN or VZM35-SN light switch source_url: https://raw.githubusercontent.com/nwithan8/configs/main/home_assistant/blueprints/automations/inovelli_led_temperature.yaml domain: automation input: temp_sensor: name: Temperature Sensor description: The temperature sensor to monitor selector: entity: domain: sensor device_class: temperature min_temp: name: Minimum Temperature description: The minimum temperature. Anything below this will be displayed as the minimum temperature (no LEDs) default: 0 selector: number: # You're literally dead at either of these temperatures min: -200 max: 199 unit_of_measurement: degrees mode: box max_temp: name: Maximum Temperature description: The maximum temperature. Anything above this will be displayed as the maximum temperature (all LEDs) default: 100 selector: number: min: -199 max: 200 unit_of_measurement: degrees mode: box switch: name: Inovelli VZM31-SN or VZM35-SN description: Which light switch to program selector: device: integration: zha manufacturer: Inovelli duration: name: Duration description: How long the effect should last, in seconds (1-254, 255 for indefinite) selector: number: min: 1 max: 255 default: 255 level: name: Intensity description: How intense the light should be, percentage (0-100) selector: number: min: 0 max: 100 default: 50 color: name: Color description: The color the light should be, (0-254, 255 for white) selector: number: min: 0 max: 255 mode: box default: 0 mode: single max_exceeded: silent variables: temp_sensor: !input temp_sensor temperature: "{{ states(temp_sensor) | float(0) | round(1) }}" solid_led_effect_code: 1 off_led_effect_code: 0 led_command: 3 # Set individual LED max_temp: !input max_temp min_temp: !input min_temp level: !input level duration: !input duration switch: !input switch color: !input color off_color: 255 # White temperature_range: "{{ max_temp - min_temp }}" led_range: 7 leds_to_turn_on: "{{ (temperature - min_temp) / temperature_range * led_range | round(0) | int }}" trigger: platform: state entity_id: !input temp_sensor action: - repeat: count: "{{ led_range }}" sequence: - service: zha.issue_zigbee_cluster_command data: ieee: > {{ (device_attr(switch, "identifiers")|list).0.1 }} endpoint_id: 1 cluster_id: 64561 cluster_type: in command: "{{ led_command }}" command_type: server # Index starts at 1 like an idiot params: "led_number": "{{ repeat.index - 1 }}" "led_effect": > {%- if repeat.index - 1 <= leds_to_turn_on -%} {{ solid_led_effect_code }} {%- else -%} {{ off_led_effect_code }} {%- endif -%} "led_color": > {%- if repeat.index - 1 <= leds_to_turn_on -%} {{ color }} {%- else -%} {{ off_color }} {%- endif -%} "led_level": "{{ level }}" "led_duration": "{{ duration }}" manufacturer: 4655